Control Panel Installation
Proceed as follows:
1. Open the control panel by removing two
screws from the front cover. Removethecover
by slidingitup slightly todisengage the bottom
clip, disconnect the earth bonding cable from
the spade connection on the front cover, then
lift clear.
2. Notethepositionofthecableentriesasfollows:
(a) Plastic cable entriesand 20mm knock-outs
top and bottom for trunking.
(b) Eight 20mm cable entries for detection,
alarm and remote keypad cables.
(c) A 20mm cable entry for mains (240V)
above the mains input terminal block on
the right hand side of the control panel
back box.
+
The mains cable must enter the control
panel through its own cable entry and
must not be mixed with other cables.
3. Hold thecontrolpanelback boxintherequired
position (keyhole to the top) and mark the
centre of the keyhole position. Remove the
back box, drill and plug the hole.
4. Screw a No 10 screw into the plugged hole.
Re-position the back box and mark the
remaining four securing holes. Remove the
back box, drill and plug the holes.
5. Re-position the back box and pass all cables
into the base via the trunking holes or
knockouts, grommeting as appropriate.
6. Secure the back boxusingnotlessthan 30mm
x No 10 screws through the four dished 5mm
holes.
7. If required install and connect the following:
(a) Stand alone digicom or RedCARE STU.
(b) Plug-on digicom type DC54, DC58 or
DC58M.
(c) Output modules type CPA6.OM.
(d) Printer type DATAC or serial RS232 via a
printer adapter (MPA).
(e) Relay module type RM.3A.
+
When replacing the cover, always
ensure that the earth bonding lead is
connected to the spade connection
on the front cover.
Key-hole mounting Lid tamper Mains cable entry
Mains fused
terminal block
Mains
transformer
Printed Circuit Board (PCB)Earth bonding lead
(connected to front cover)
Space for a 7 Ah
lead acid battery
20mm cable
entries
Figure 5. TS790 & TS900 Control Panel Layout