Programmable Outputs
The TS790/900 has many programmable outputs
which can be used to drive relays, LED’s etc. Each
output can be programmed for a different
function, see "Programmable Output Types" on
page 22.
Control Panel Outputs
Thecontrolpanel hasfourprogrammableoutputs:
[1] Set of voltage free change-over contacts
rated at 1 Amp.
[-2] Switched -ve output rated at 500mA.
[+3] Switched +ve output rated at 500mA.
[+4] Switched +ve output rated at 500mA.
Node Outputs
EachTS900 Nodehastwoprogrammableoutputs:
[+A] Switched +ve output rated at 100mA.
[-B ] Switched -ve output rated at 100mA.
Remote Keypads & TS700.LECs
Each remote keypad and TS700 LEC has one
programmable output:
[O/P] Switched -ve output rated at 100mA.
RelayRelay
Smoke
Detector
Smoke
Detector
Relay available from
RS components
P/No. 346-946.
Capable of switching
mains voltages
Relay available from
RS components
P/No. 346-946.
Capable of switching
mains voltages
+ 12 V + 12 V
Aux 12 V
Aux 0V
-ve O/P
+ve O/P
(Programmed as Alarm / Bell / etc)
(Programmed as Alarm / Bell / etc)
(Programmed as Detector Reset)
(Programmed as Detector Reset)
Aux 0V
Aux 0V
Aux 0V
+ve Outputs -ve Outputs
1K0 Ohm Resistor
12V Buzzer
RS Part No. 245-051
12V Buzzer
RS Part No. 245-051
1K0 Ohm Resistor
LED (Light Emiting Diode) LED (Light Emiting Diode)
-Ve O/P
-Ve O/P
-Ve O/P
+ve O/P
+ve O/P
+ve O/P
Aux 12V
Aux 12V
Aux 12V
0V 0V
Diode (IN418)Diode (IN418)
Figure 24 Output Examples
MPA
or DCI
DATAC or RS232 printer
CPA6 Printer
RS232 Data
Connect to JP1
PRINTER
Connect to JP1
PRINTER
1
CPA6 P
DATA IN
POWER
PAPER FEED
Figure 25 Printer Connections
TS790 & TS900 Installation Manual System Installation