TS700 LED Remote Keypad
The TS700 remote keypad has a 4 character LED
display.
TS700 Remote Arming Station
The TS700 remote arming station only has two
indicator LED's,a power LEDand aprogrammable
function LED which follows the programmable
output.
Installation Procedure.
+
Always ensure that all power (mains
and battery) is removed before
making any connections to the
remote keypad.
1. Separate the cover and base by using a
screwdriver to push 2 of the clips (top or
bottom) inward from the base indents, then lift
thecoverassembly,notingthatthe PCBisfixed
to the under side of the cover.
2. Hold the base in position (keyhole to the top)
and mark the three securing holes, drill and
plug the wall as required. Pass all the cables
into the base via the cable entry points as
appropriate and secure the base to the wall.
3. Connect “Remote Network” and detection
circuit cables to the appropriate terminals, see
Figure 8.
4. Set the I/D selector jumper link to the required
position:
I/D Selector Circuit A Circuit B
Panel
Output
1 09 10 5
2 11 12 6
3 13 14 7
4 15 16 8
ENG/NULL N/A N/A N/A
No two remote keypads or LECs should
have the same I/D.
If the I/D is set to “ENG” the remote keypad
will function as an Engineers keypad
allowing it to be plugged onto the control
panel so that system programming and
testing may be carried out (see Engineer’s
Keypad).
5. If the remote keypad has a "ENT" key
enabled/disable link it can be used to limit the
functionality of the remote keypad. If the "ENT"
key is enabled the remote keypad can be
used to set/unset and access all user menus.
If the "ENT" key is disabled the remote keypad
can only be used to set and unset the system.
6. If the remote keypad has a “Ward Sounder
Control”linkitcanbeusedto makethe remote
keypad sounder follow the programmable
output. When the link is set to the disabled
2 Detection
circuits
Programmable output
switched -ve
@100mA
I/D
Selector
Tamper
Switch
A B
REMOTE
I/D
1
2
3
4
ENG
C D E
O/P-
CIRCUIT B
CIRCUIT A
ZB
ZA
TB
TA
Remote network
connections
LED Module
DISABLED
WARD SOUNDER
CONTROL
DISABLED
'ENT' KEY
Figure 10 TS700 Remote Keypad Layout
Tamper
Switch
2 detection
circuits
Programmable output
switched -ve
@100mA
I/D
Selector
A B
REMOTE
I/D
1
2
3
4
DISABLED
DISABLED
WARD SOUNDER
CONTROL
'ENT' KEY
ENG
C D E
O/P-
CIRCUIT B
CIRCUIT A
ZB
ZA
TB
TA
Remote network
connections
Figure 11 TS700 Arming Station Layout
TS790 & TS900 Installation Manual System Installation
9