Panel Outputs
Outputs 1 - 4 on the the control panel and remote
keypad outputs 5 - 8 can be programmed to any
of the output types shown on page 22 .
Digicom Outputs
The 8 digicom outputs on the control panel PCB
can be programmed to any of the output types
shown on page 22. In addition, all outputs can be
inverted, see “Configuration option 19” on page
32.
Digicom Channels
The 8 plug-on digicom channels can be
programmed to any of the output types shown on
page 22.
Programmable Output Types
No/Type Description
000
Bell On
Activates when the main Bell trigger is
on and deactivates at the end of the
Bell Duration time or when the alarm is
cancelled by the user.
001
Strobe On
Activates when the Strobe trigger is on,
and deactivates when the alarm is
cancelled by the user.
002
Switch 12V
Activates when the system is set and
deactivates when an alarm occurs or
the system is unset. This output is
normally used for latching detectors.
003
Detector Reset
Normally active at all times and
deactivatesfor3secondswhena valid
passcode is entered prior to setting the
system. This output is normally used for
detector that required power to be
removed in order to reset them, e.g.,
smoke detectors.
004
Walk Test
Activates when the “Walk Test” option is
selected and deactivates when the
“Walk Test” option is finished.
005
Alarm
Activates when an intruder alarm is
detected and deactivates when the
alarm is reset or aborted.
Panel Output ?
Enter Number > -
Panel Output 1
is type > 004
Panel Output 1
is type > 021
Enter new output type
Type No.
1
Enter output No. 1 - 8
e.g. 1
ENT
e.g. 021
Engineers menu 1
Select Options :-
StarburstLCD
LED
E1-
ENGR 1 -
PAN.-
PANEL -
004
004
021
021
Panel Outputs Flowchart
Digi Output ?
Enter Number > -
Digi Output 7
is type > 020
Digi Output 7
is type > 071
Enter new output type
Type No.
2
Enter output No. 1 - 8
e.g. 7
ENT
e.g. 071
Engineers menu 1
Select Options :-
StarburstLCD
LED
E1-
ENGR 1 -
DIG.-
DIGI OP -
020
020
071
071
Digi Outputs Flowchart
Digi Channel ?
Enter Number > -
Digi Channel 8
is type > 011
Digi Channel 8
is type > 055
Enter new output type
Type No.
3
Enter channel No. 1 - 8
e.g. 8
ENT
e.g. 055
Engineers menu 1
Select Options :-
StarburstLCD
LED
E1-
ENGR 1 -
Dc5.-
DIGI CH -
011
011
055
055
Digi Channels Flowchart
Engineer's Menu 1 TS900 Installation Manual
22
Comentarios a estos manuales