Log Event Codes
Reset User Code 1
This option allows the installation engineer to reset
the master user (user 01) back to the factory
default code of “5678". This feature is useful when
the master user has forgotten their passcode or
has accidentally changed it without realising. This
operation is logged.
Start Call Back
If the the system is fitted with a DC58M
digi-modem, it is possible for the installation
engineer to initiate an upload sequence to a
remote site (normally the alarm company). Once
the communication link is established with the
remote site, data can be sent and received from
the control panel. This feature is only compatible
with Menvier Lineload software version 2.2 or
above.
LCD Starburst LED Description
TAMPER 01-56
TAMP'R 01-56
TA. 01-56
Tamper alarm from circuit.
TESTCCTS OFF
TEST OFF
To
All circuits taken off “Test”
TESTFAIL 01-56
T. FAIL 01-56
TF. 01-56
Circuit failed during “Test”.
TIMECHANGED
TIME CHG
Tc
System time changed
UNSET WARDA/B/C/S
UNSET A/B/C/S
Un. ABCS
Wards A, B, C or System Unset.
WALKTEST
WALK TST
cT
System “Walk Test” selected.
Press ENT to
Reset User 1 ?
to reset user 1
0
ENT
Engineers menu 2
Select Option :-
StarburstLCD
LED
E2 -
ENGR 2 -
REST
USR 1
RESET
USER 1 ?
Reset User Code Flowchart
Call Number 1
0181 12345678
Call back No.
Tel No.
A
1
ENT
Engineers menu 2
Select Option :-
2
3
= Call No. 2
= Call No. 1
= Call No. 3
to start call
back sequence
SYSTEM OPEN
09:00 Sun 28 APR
StarburstLCD
LED
E2 -
ENGR 2 -
No. 1
CALL NO.1
OPEN
OPEN
Start Call Back Flowchart
Engineer's Menu 2 TS900 Installation Manual
40
Comentarios a estos manuales