Log Event Codes
LCD Starburst LED Description
DATE CHANGED
DATE CHG
Dc
System Date changed.
DEFAULT CODE
DEFLT 01
DF
User passcode (01) reset to 5678 by the engineer.
DURESS01-31
DUR’SS 01-31
Du. 01-31
Duress alarm from user passcode (01-31).
ENTRY01-56
ENTRY 01-56
En. 01-56
Entry timer started by circuit (01-56).
ENTRYALARM 01-56
EN.ALM 01-56
EA. 01-56
Entry timed-out alarm from circuit (01-56).
FACTORY RESTART
FACT. RST
Fr
System “Factory Restarted”.
FIRE ALARM01-56
FIRE 01-56
FA. 01-56
Fire alarm circuit activated.
FIRSTKNOCK 01-56
FIRST 01-56
Fn. 01-56
The first activation of a Double Knock circuit.
FUSEBLOWN 01
FUSE 01
FB. 01
Control Panel 12V Auxiliary Fuse blown.
INACTIVECCTS 01-56
INACT 01-56
IA. 01-56
Inactive circuits during the Unset condition.
KEYPOINT 01-56
KEY.SW 01-56
So. 01-56
Key point operation from circuit (01-56).
LINEFAULT
LINE FLT
LF
Telephone line fault detected.
LINERESTORED
LINE OK
Lr
Telephone line fault restored.
MODEM LOCK-OUT
LOCK-OUT
LO
Modem failed to communicate.
NO EVENT
NO EVENT
--
No log event.
NODEADDED 01-05
N.ADD 01-05
NA. 01-05
Node added to the system.
NODEFUSE 01-05
N.FUSE 01-05
NF. 01-05
Node fuse blown.
NODEREMOVED 01-05
N.REM 01-05
Nr. 01-05
Node removed from the system.
NODETAMPER 01-05
N.TMP 01-05
NT. 01-05
Node cover removed.
ON-SITE RESTART
SITE. RST
Sr
System “On-Site” restart.
OMITS REMOVED
OMIT REM
Or
Previously omitted circuits reinstated.
PA ALARM01-56
PA.ALM 01-56
PA. 01-56
Panic Alarm circuit activated.
PA CODE 01-31
PANIC 01-56
PC. 01-31
Panic Alarm passcode entered.
PANEL LIDTAMPER
LID TAMP
LT
Control panel lid removed.
PART SETA/B/C
P.SET A/B/C
PS. A/B/C
System Part-Set using one of the A, B, or C buttons.
PASSCODE 00-31
USER 00-31
Ur. 00-31
User passcode entered. (00-31).
REMOTE ADDED 01-04
R. ADD 01-04
RA. 01-04
Remote Keypad added to the system.
REMOTE RESET
REM RST
rc
System reset by “Remote Reset” passcode.
REM REMOVED01-04
R. REM 01-04
rr. 01-04
Remote Keypad removed from system.
REM SERVICECALL
R.S. CALL
SC
Remote service call via “Lineload” software and PC.
REM TAMPER01-04
R. TMP 01-04
rT. 01-04
Remote Keypad cover removed.
SERVICECALL END
R.S. END
SE
Remote service call finished.
SERVICEREQUIRED
SERVICE
rS
Service required
SETFAIL
SET FAIL
SF
System failed to Set.
SETWARDA/B/C/S
W. SET A/B/C/S
ST. ABCS
Wards A, B, C or System Set.
SYSTEMOPEN
SYS OPEN
OP
System fully unset.
SYSTEMRE-ARMED
RE-ARMED
rA
System re-armed all healthy circuits.
SYSTEMSET
FULL SET
FS
System fully set.
TS900 Installation Manual Engineer's Menu 2
39
Vista de pagina 42