TS2500
TS2500 22 of 26 496513 Issue A
Hotkey Option
1
View Circuits
A/C = Scroll up and down
ENT = Toggle text / location
2
Set System Time
B = Toggle BST / GMT
3
Set System Date
4
Change Passcode (Engineers)
5
Alter Chime Circuits
A/C = Scroll up and down
ENT = To edit
1 = Chime tone 1
2 = Chime tone 2
3 = Chime tone 3
0 = Disabled
6
Alter 24hr Group
1-8=Select/deselect wards displayed
A/C = Toggle wards A-H or I-P
B = Select/deselect all wards
7
Print System Log
8
Alter Circuit Wards
A/C = Scroll up and down
ENT = To edit
1-8=Select/deselect wards displayed
A/C = Toggle wards A-H or I-P
B = Select/deselect all wards
9
View System Log
A/C = Scroll up and down
B = Toggle user name / No
B = Toggle event / ward
B = Toggle circuit No / circuit text
A
Start Call Back Sequence
1 = Call Back No 1
2 = Call Back No 2
3 = Call Back No 3
B = Enter number required
ENT = Start call back sequence
B
Reset User Code 1
ENT = Reset user 1 to 5678
C
Set BST/GMT Dates
0
Remote Service Options
B = Toggle Enabled / Disabled
Hotkey Option
1
Program Time Switches
A = Time switch 1 1 = On Time 1
B = Time switch 2 2 = On Time 2
C = Time switch 3 3 = On Time 3
4 = Off Time 1 7 = 1st operates on
5 = Off Time 2 8 = 2nd operates on
6 = Off Time 3 9 = 3rd operates on
0 = Manually switch output
2
Part Set Groups
1 - 9/0 = Select part set group
ENT = Edit
3
Use On-Line Keypad
4
Edit User Names
A/C = Scroll up and down
ENT = Edit text
5
Part Set Text
1 - 9/0 = Select part set group
ENT = Edit text
6
Circuit Text
A/C = Scroll up and down
ENT = Edit text
7
Custom Text Menu
0 = Reset message 5 = Banner message
1 = Location text 6 = Part set banner
2 = Printer header 7 = Aux. Tamper 1
3 = Rem reset msg 8 = Aux. Tamper 2
4 = Printer prefix 9 = Modem string
8
Equipment Outputs
A/C = Scroll up and down
B = Toggle outputA/B
9
Built In Tests
Software Version
1 = Voltage
2 = Current
3 = Circuit Resistance
4 = Digicom Outputs (Panel)
5 = Test panel outputs
6 = Test NODE outputs
7 = Confirm Network devices
8 = Test Keypad display
9 = View Network devices
A/C = Network errors
A/C = False setting routine
A/C = Test digicom channels (Plug-on)
A
Custom Outputs
B
Custom Circuits
1-8=Select custom output1-8
ENT = Edit
1 = Toggle unset A/C = Bell required
2 = Toggle part set A/C = Digi required
3 = Toggle set A/C = Sounder required
A/C = Warning required
A/C = Trig Custom o/p
C
Digi-modem Options
1 = Call back No 1 6 = Program digicom
2 = Call back No 2 7 = Digi Baud rate
3 = Call back No 3 8 = COM1 Baud rate
4 = Modem password 9 = Internal digicom
5 = Modem site No 0 = Reset digicom
0
Activity Count
A/C = Scroll wards
B = Reset counter
Engineers Menu 2 Engineers Menu 3