Switch OFF ON
1 XNODE circuits A &
B enabled
Remote keypad 1
circuitsA&Benabled
2 XNODE circuits C &
D enabled
Remote keypad 2
circuitsA&Benabled
3 XNODE circuitsE&F
enabled
Remote keypad 3
circuitsA&Benabled
4 XNODE circuits G &
H enabled
Remote keypad 4
circuitsA&Benabled
Remote keypads cannot be multi-tasked
between each other when connected to the
XNODE, i.e. If remote keypad 1 is in operation,
remotekeypads 2, 3 and 4 are locked-out and
will show “SYSTEM IS BUSY PLEASE WAIT”.
The remote keypads follow the ward
assignment of the XNODE, i.e. If the XNODE is
assigned to ward A then remote keypads 1-4
connected to thatXNODE are also assigned to
ward A.
Theloudspeakerandremotekeypadsounders
will followthewardassignmentoftheXNODE.
The programmable output on the remote
keypads are mapped as follows: Remote
keypads 1 and 3 follow XNODE output A and
remote keypads 2 and 4 follow XNODE output
B.
TS2500
TS2500 10 of 26 496513 Issue A
Data
Network
Control Panel
100 metres 100 metres
100 metres 100 metres 100 metres
1Km(Max.)
Out
In
XNode XNode XNode XNode XNode
XNode
XNode XNode
I/D=1 I/D=3 I/D=6 I/D=7 I/D=8
I/D=5
I/D=2 I/D=4
Out
In
Out
In
Out
In
Out
In
XNodeXNode
I/D=10I/D=9
Out
In
Out
In
XNode
I/D=11
Out
In
Out
Out
Out
In
In
In
100 metres
4-Core
4-Core
100 metres
100 metres 100 metres
1Km
(
Max.
)
Daisy-chained Connections
Star and Daisy-chained Connections
NOTE:
The maximum number of devices
that can be "Star" connected from
the output of the Node or control
panel is 4.
XNodes
5to16
Out
In
XNode XNode XNode XNode XNode
I/D=1 I/D=2 I/D=3 I/D=4 I/D=16
Out
In
Out
In
Out
In
Out
In
Data
Network
Control Panel
Figure 6 XNODE Connection Methods
Network Wiring
XNODE Wiring
TheXNODErequiresa4 corecablefor interconnection,
and up to 16 may be connected in a “daisy-chain” or
“star” configuration. The distance between each
XNODE must not exceed 100 metres. The total
distance to last XNODE must not exceed 1000 metres.
Power for detectors is provided by the Aux. +/-
terminals.
Wiring Remote Keypads to an XNODE
Up to four remote keypads can be connectedto each
XNODE, they can be connected in either a “star” or
“daisy-chain” configuration. The distance to the
furthest remote keypad from the XNODE must not
exceed 100 metres. Power for detectors are provided
by the A(+) and B(-) terminals.
The detection circuits in the XNODE can either be
mapped to the XNODE or the the remote keypads by
setting the 4-way “Remote Zone Enable” switch as
shown in the table above: