Key Functions
Engineer’s Reset
1. Key in engineer code default 1234. Display
shows “Engineer’s Menu 1”.
2. Press ] display shows “Engineer Onsite”.
This message will be cleared the next time a valid user
passcodeisenteredorbyexitingtheengineer'smenu
1 by pressing C and then [.
Relearn Required Message
When the system is powered up after a factory restart,
the remote keypads will display “RELEARN REQUIRED”.
On entering your engineer’s passcode the system will
automatically select the “Confirm Network Devices”
option. Afterconfirmingthecorrectnumberof devices
the “RELEARN REQUIRED” message will be cleared.
Once cleared, entering your engineer’s passcode will
select “Engineer’s Menu 1”.
Resetting the Engineer’s Passcode
If the installation engineer has inadvertently changed
the engineer’s passcode or the passcode has been
forgotten, the passcode can be reset back to 1234
without losing any other programmed data. This
procedure can only be used providing a user
passcode is available:
1. Ensure that the system is unset and a user
passcode is available.
2. Remove the cover from the control panel, this
will cause a “Panel Lid Tamper” alarm.
3. Ask the user to enter their passcode to silence
the alarm.
4. Place the blade of a small screwdriver between
the pins labelled “FACTORY RESTART”. A multi-tone
sound indicates the engineer’s passcode has
been reset.
5. Replace the control panel cover. At the remote
keypad enter 1234. The display will show
“Engineer’s Menu 1”.
Loading Defaults
To return panel to factory defaults:
1. Power down panel
2. Short factory restart pins
3. Power up battery & mains
4. Remove short
5. Enter 1234 to silence sounders
6. Replace the control panel cover. At the remote
keypad enter 1234. The display will show
“Engineer’s menu 1”.
Initial Power-Up
To power up the system for the first time:
1. Place a small screwdriver blade between
the pins on the control panel PCB, marked
“FACTORY RESTART”. This will ensure the
factory default parameters are set.
2. Switch on the 230V mains supply and remove the
screwdriver blade after 5 seconds.
3. Check that the powerLED on the control panelPCB
is illuminated.
4. Check that the remote keypads display “Panel Lid
tamper”. The remote keypad sounders and
extension loudspeakers will be operated.
5. Enter the engineer’s passcode (default 1234)
to silence the sounders.
6. Connect the standby battery.
Bell Test/Walk Test
Please refer to User Menu 1, No’s1&2respectively.
TS2500
496513 Issue A
19 of 26 TS2500
Comentarios a estos manuales