Display Messages (Cont.)
46
Fault Finding TS790+ & TS900+ User Manual
PA CODE 09
08:30.45 28/04
Panic alarm generated by user 09 (PA Code). Refer
to "Resetting After an Alarm" on page 11.
PANIC 09
PC
.
09
PANEL LID TAMPER
08:30.45 28/04
Control panel cover has been removed. Refer to
"Resetting After an Alarm" on page 11.
LID TAMP
LT
PHONE LINE FAULT
08:30.45 28/04
Telephone line fault (systems fitted with remote
signalling only). To silence the alarm, simply enter a
valid passcode. If the fault persists contact your
installation company for further advice.
LINE FLT
LF
PSU OVERLOAD !
08:30.45 28/04
The power supply within the control panel is being
overloaded. Enter a valid passcode to silence the
alarm and contact your installation company for
further advice.
OVERLOAD
OL
REM REMOVED 01
08:30.45 28/04
Remote keypad 01 has been disconnected from the
system or has failed. Contact your installation
company for further advice.
R. REM 01
rr
.
01
REM TAMPER 01
08:30.45 28/04
The cover of remote keypad 01 has been removed.
Refer to "Resetting After an Alarm" on page 11.
R.TMP 01
rT
.
01
SERVICE REQUIRED
08:30.45 28/04
Your system requires a service visit. The system can
still be used as normal, but you should contact your
installation company for further advice.
SERVICE
rS
SYSTEM IS BUSY
PLEASE WAIT.
Another user is operating the system from a different
remote keypad. When he/she has finished, all
remote keypads will revert to normal.
BUSY
BUSY
TAMPER 05
08:30.45 28/04
Tamper alarm from detection circuit 05. Refer to
"Resetting After an Alarm" on page 11.
TAMP'R 05
TA
.
05
NODE TAMPER 01
08:30.45 28/04
The cover of Node 01 has been removed. Refer to
"Resetting After an Alarm" on page 11.
N.TMP 01
NT
.
01
MAINS POWER OFF
08:30.45 28/04
Mains power to the system has been removed. Enter
a valid passcode to silence the alarm. The system
will be maintained from its standby battery for a
minimum of 8 hours. If the mains power is not
restored after 8 hours contact your installation
company for further advice.
A.C. OFF
PF
PA ALARM 08
08:30.45 28/04
Panic alarm from detection circuit 08. Refer to
"Resetting After an Alarm" on page 11.
PA.ALM 08
PA
.
08
Press ENT to
Set with L.F. ?
You are trying to set the alarm system with a
telephone line fault (L.F.). If you press [ the system
will continue to set or part-set but your remote
signalling device may not work if the alarm is
triggered.
SET
SET
WITH L.F.
L
.
F
.