Bell Test - 1
This option allows the internal sounders, external bells and external strobe lights to be tested by
the user. When selected each device will operate in sequence for nine seconds.
1. Ensure that "User menu 1" is selected.
Press 1 to select the Bell Test option.
2. The internal sounder(s) will operate for 9
seconds, press [ to advance to the next
test or ] to end the test. The display will
count down the remaining time e.g.,
3. The external bell(s) will operate for 9
seconds, press [ to advance to the next
test or ] to end the test. The display will
show the remaining on time e.g.,
4. The external strobe(s) will operate for 9
seconds, press ] to end the test. The
display will show the remaining on time e.g.,
5. The display will automatically return to
"User menu 1" when all three tests are
completed.
Walk Test - 2
This option allows the user to test the function of individual detection circuits without causing an
alarm. As each circuit is activated the circuit number and status are displayed and the internal
sounders generate a two tone "Chime" sound. Once the test has been completed the tested
circuits can be reviewed in numerical order.
1. Ensure that "User menu 1" is selected.
Press 2 to select the Walk Test option. The
display will show:
2. Activate detection circuits in any order
by opening doors with alarm contacts and
walking in front of movement detectors,
e.g., activate circuit 05 then circuit 03:
3. When the test has been completed,
press ], he display will show:
4. The display will now automatically scroll
through the circuits that were tested in
numerical order. The current status of the
circuit is also displayed. The [ button can
be used to scroll through the tested circuits
more quickly, if desired.
5. Press ] to leave the Walk Test option
and return to "User menu 1".
18
User Menu 1 TS790+ & TS900+ User Manual
Bells...ON > 09
Press ESC to end
ON 9
ON9
Strobe...ON > 09
Press ESC to end
ON 9
ON9
ON 9
ON9
Sounder.ON > 09
Press ESC to end
Office Door
CCT 05 Active
CCT 05-A
05-A
x NONE x
NONE
Walk Test
Press ESC to end
Office Detector
CCT 03 Active
CCT 03-A
03-A
Tested CCTs were
Press ESC to end
CCT 03-H
03-H
Office Detector
CCT 03 Healthy
CCT 03-H
03-H
Office Door
CCT 05 Healthy
CCT 05-H
05-H
A = Active
H = Healthy
S = Shorted
T = Tamper