Menvier Security TS900+ Manual de usuario Pagina 24

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 57
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 23
1. Ensure that "User menu 1" is selected.
Press 5 to select the Enable Chime option.
The display will show:
2. Select the chime option by pressing:
0 Enabled/Disabled
1 Disabled (OFF)
2 Enabled (ON 1)
3 Enabled in P.Set (ON 2)
4 Enabled in Unset (ON 3)
5 Enabled o/p A On (ON 4)
B Toggles between options 1 - 5
e.g., to disable the "Chime" feature
press "1", the display will show:
3. When the display shows the required
setting press [ to accept. The display will
automatically return to "User menu 1".
Omit 24 Hour Group - 6
The installation company or master user may group together detection circuit types 24 Hour and
Auxiliary so that they can be omitted when the system is unset. This menu option allows the user
to temporarily omit the circuits that have been assigned in the 24 Hour group. This will allow them
access to the areas that are protected by 24Hr and Auxiliary type detection circuits, e.g.,
Loading bay doors, Fire Doors, etc.
1. Ensure that "User menu 1" is selected.
Press 6 to select the Omit 24 Hour Group
option. The system remains unset and the
display will show:
2. To re-reinstate the 24 hour Group repeat
step (1). The display show the "SYSTEM OPEN"
message.
If a low tone is generated when this menu option is selected then no detection circuits
have been assigned to the "24 Hour Group"
Omitting Circuits - 7
Sometimes it may be necessary to omit detection circuits when setting or part-setting the
system. This allows the user access to the omitted area(s) when the system is set or part-set. It is
also possible to omit 24hr or Auxiliary circuits so that access to these areas can be obtained
when the system is unset.
When the alarm system is unset or when a user passcode is entered, "Night" detection circuits
that were selected as omitted are automatically re-reinstated. Only detection circuits that have
been programmed by the installation company as "Omit" may be selected when using this
menu option.
20
User Menu 1 TS790+ & TS900+ User Manual
Chime ccts are
Disabled
OFF
OFF
ON 1
ON1
Chime ccts are
Enabled
CIRCUITS
CCTS
CCTS ISOLATED
08:30 Sun 28 APR
OMITTED
ISOL
OPEN
OPEN
SYSTEM OPEN
08:30 Sun 28 APR
Vista de pagina 23