TSD402 & TSD401
Engineers Quick Reference Programming Chart
Key Function Action Options
1
Program Zones Press 1-6 to toggle zone types
Press AWAY to end
1 Zone 1
2 Zone 2
3 Zone 3
4 Zone 4
5 Zone 5
6 Final Exit
= Night or Access
= Night or Access
= Night or KeySwitch
= Night or Fire
= Night or PA
= Exit or Access
2
View Log
Press HOME to advance
Press AWAY to end
3
Walk Test Activate detectors
Press AWAY to end
4
Exit Time Enter 3 digit time
Press HOME to accept
Enter time between 001 - 255 (seconds)
5
Entry Time Enter 3 digit time
Press HOME to accept
Enter time between 001 - 255 (seconds)
6
Bell Duration Enter 3 digit time
Press HOME to accept
Enter time between 000 - 255 (minutes)
Note: 000 = Continuous
7
Change Engineer
Code
Enter new 4 digit code
Press HOME to accept
8
Change Reset No Enter 3 digit code
Press HOME to accept
Enter number between 000 - 255
Note: 000 = Disable Remote Reset
9 System Options Press 1-7 to toggle system
options
Press AWAY to end
1 Bell Output
2 Setting Mode
3 Reset By
4 Re-arms
5 Keyswitch Option
6 RST Output
7 Final Exit in P/Set
= SCB or SAB
= Final Exit or Timed Exit
= User or Engineer
=1or3
= Away or Home
= Detector Reset or SW12V
= Final Exit or Night
0 Dialler Alarm Options Press 1-3 & 5-7 to toggle
options
Press HOME to accept
1 Away Fire
2 Away PA
3 Away Intruder
5 Home Fire
6 Home PA
7 Home Intruder
= Reported or not reported
= Reported or not reported
= Reported or not reported
= Reported or not reported
= Reported or not reported
= Reported or not reported
Away Return to unset