TSD402 & TSD401
TSD402 & TSD401 6of10 496523 Issue A
Initial Power-Up
1. Placeasmall screwdriverbladebetweenthepins
on the Control Panel PCB, marked FACTORY
RESTART (located top left corner). This will ensure
that the factory default values are loaded into
memory as show below:
Engineer's Passcode - 1234
User 1 Passcode - 5678
User 2 Passcode - Not programmed
Zone 1 - Night
Zone 2 - Access
Zone 3 - Night
Zone 4 - Night
Zone 5 - Night
Final Exit - Exit
Exit Time - 030 Seconds
Entry Time - 030 Seconds
Bell Duration - 020 Minutes
Remote Reset Number - 004
Bell Output - SAB (-ve Applied)
Setting Mode - Timed Exit
Reset Authority - User Reset
Number of Re-arms - 3
Operation of Key Switch - AWAY Set (Full)
Operation of RST Output - Switched 12V
Operation of Final Exit in P/Set - Final Exit
HOME Setting - Zone 1 Omitted
Dialler Alarm Options - No Alarms Report
Acknowledgement Option - Cleared by any 1
2. Switch on the 240V mains supply and remove
the screwdriver blade. The internal alarm will
bleep every 30 seconds the display will show:
CF- T.
3. Connect the standby battery. If the display
shows: BATT.FLT and the internal alarm
sounds, then the battery may have been
incorrectly connected or its voltage is below 8V.
Disconnect the battery immediately and
reconnect or replace as appropriate.
4. Push the battery into place at the bottom of the
housing and re-fit the front cover.
5. The display will show: PLEASE RE-RECORD,
this message will only be cleared when one or
more of the speech dialler messages has been
recorded.
6. Enter the engineer's passcode (default
12
34
), the display will show: ENGR. OPTION -
(engineer programming menu selected)
7. Thetelephoneleadcan now bepluggedintothe
telephone socket.
8. Fitthebatterylink intheexternalsiren andreplace
cover.
9. The system is now ready for engineer
programming
Log Event Codes and Descriptions
Display Description
AC OFF
Mains power removed.
AC ON
Mains power restored.
AU PL TA
Auxiliary or panel lid tamper alarm.
BATT FLT
Battery fault (battery reversed or
below 10.5V).
CCT AL -
Full alarm from zone1-5(F=Final
Exit when part-set).
CODE TA
Code Tamper (4 incorrect
passcode entries).
ENTRY TO
Entry timed-out (system not unset
after activating F/Exit zone).
FIRE AL
Fire Alarm activated.
SET A
AWAY Set.
SET FAIL
System failed to set (zone still active
at end of exit time).
SET H
HOME Set.
USER -
User 1 or 2 passcode entered (User
3 = keyswitch).
--------
No Event