Key Functions
Engineer’s Reset
1. Enter Engineer’s code default 1234. The display will
show ENG OPTION. you are now in Engineer’s
Mode.
2. Press to return to unset.
Loading Defaults
1. Power down panel mains and battery.
2. Place a small screwdriver blade between the pins
on the control panel PCB, marked Factory Restart.
3. Power up panel battery and mains.
4. Remove the screwdriver blade.
5. Enter 1234. The display will show ENG OPTION.
The panel is now back to Factory Default
Programming.
Bell Test/Walk Test
Pleaserefertouseroptionsnumbers1&2respectively.
496523 Issue A 7of10 TSD402 & TSD401