Output Modules Installation (CPA6.OM)
Output Modules (CPA6.OM) can be used to
provide a set of outputs to LEDs or relays to indicate
either circuit alarm activations or circuit mimic
activations. The first output module connected to
the system will indicate circuits 1 to 8, the next
modules will indicate circuits 9 to 16 etc. Output
modules are normally fitted inside the equipment
they are controlling and may be positioned up to
500 metres away from the main panel. The output
module should be used and connected in
accordance with the instructions provided with it.
Connecting a Printer
The TS790/900 supports two type of printers, the
CPA6 printer (no longer available) and any
standard RS232 printer. When using an RS232
printer a DCI/MPA printer adaptor will be required.
Menvier Security supply a DATAC printer kit which
consists of a portable RS232 printer, charger unit
and DCI/MPA adaptor.
Using the CPA6 Printer
1. Plug the CPA6 printer directly on to the PRINTER
plug (JP1) on the main control panel PCB.
2. The printer will printout a header, when finished
the system program details and event log can
be printed.
3. When finished unplug the printer. If the printer is
left connected events will be printed as and
when they occur.
Using the DATAC / RS232 Printer
1. Plug the DCI/MPA on to the PRINTER plug (JP1)
on the main control panel PCB.
2. Plug the other end of the DCI/MPA into the
DATAC or RS232 printer.
3. In order for the printer to work correctly ensure
the printer is set to the following:
Baud rate = 4800
Parity = None
Start bits = 1
Stop bits = 2
Data bits = 8
DTR = Normal
4. When set-up correctly the system program
details and event log can be printed.
5. When finished unplug the MPA/DCI. If the
printer is left connected events will be printed
as and when they occur.
16
System Installation TS790 & TS900 Installation Manual
PL1
1k Resistors
LED's
1234
567
+12V IN
+12V OUT
+12V OUT
8
PL2
To next OM
Connect to plug
labelled OUTPUT
MODULE
100m
Figure 21 Output Module Connections
DC58M
Telephone
Network
V21.
Modem
Alarm Receiving
Centre
TS790/900 Control
Panel
Figure 20 DC58M Digi-modem Schematic
Comentarios a estos manuales