Control Panel PCB Layout
6
System Installation TS790 & TS900 Installation Manual
OUTPUT MODULE PRINTER
1AMP
NODE SUPPLY
REMOTE
KEYPAD
JP3
DIGI-MODEM
FACTORY
RESET
Node Network
connection terminals
(TS900 Only)
Auxiliary 12V
Auxiliary 12V
Remote
keypad
Network
connections
Programmable
Detection
Circuits 1 - 8
Digicom Outputs
Programmable @ 100mA
12V Digicom Power
Line Fault Input (12V = Fault)
Auxiliary Tamper
Extension loudspeaker
External sounder
connections
21V A.C. from mains
transformer
Earth connection
Panel Outputs
O/P 1 = Change over contacts
O/P 2 = Switched -ve @ 500mA
O/P 3 = Switched +ve @ 500m
O/P 4 = Switched +ve @ 500m
Z1
Z2
Z3
Z4
Z5
Z6
Z7
Z8
T1
T2
T3
T4
T5
T6
T7
T8
CIRCUIT 1
CIRCUIT 2
CIRCUIT 3
CIRCUIT 4
CIRCUIT 5
CIRCUIT 6
CIRCUIT 7
CIRCUIT 8
RR
JP5
JP6
SPEAKER
VOLUME
NOVRAMS
AUX 12V
BELL 12V
1AMP
BATTERY FAULT
POWER
ON
EARTH
TRG
-
STB
-
TR- H/O
-
H/O
+
SPK
+
AUX
TAMP
LINE
FLT
+DC
1234
DIGITAL COMMUNICATOR
56
78
AUX
A
REMOTE NETWORK
BCDE
+4 +3
-2
A
NODE NETWORK
OUTPUT 1
-- OUTPUTS --
B
GF
N/O N/CCOM
0V 12V
0V 12V
POWER
A. C.
V
1AMP
FS3
FS4
JP1JP4
JP2
ENGINEERS REMOTE
U2 U3
Figure 6. TS790 & TS900 Main PCB