Menvier Security TS700 Manual de instrucciones Pagina 23

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 32
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 22
Change Date
The system calendar may be changed by entering the date as four digits representing the day
and month e.g., 0207 is the 2nd July.
1. Ensure that "Engineer Menu 2 " is selected .
2. Press 3 to select the Change Dat e option.
3. Enter the date as four digits.
4. Press [ to accept.
Change Engineer's Passcode
The factorydefaultengineer'spasscode issetto1234,buttheinstallationengineershouldchange
thi s to their own pe rsonal four-digit passcode, as follows:
1. Ensure that "Engineer Menu 2 " is selected .
2. Press 4 to select the Change Engineer's Passcode option.
3. Enter the new passcode then press [ to accept.
4. A high tone will indicate accept ance. A low tone sound will
indicate tha t the passcode is not available.
Conf igure Chime Ci rcuits
This option is used to select the circuits that will chime.
1. Ensure that "Engineer Menu 2 " is selected .
2. Press 5 to select the Chime Circuits option.
3. Circuits wi ll be displayed as Y(Yes) to chime or N(No) not to
chime. Change status by pressing 0 ("toggle" action).
4. Press [ to accept(high tone) and go tonext circuit.Circuits may
be selected by number. Press ] to quit.
Conf igure 24 Hour Omit Group
This option allows the engineer to select the 24 hour circu its that will be omitted when the 2 4 ho ur
omit option is selected in "User Menu 1" option 6.
1. Ensure that "Engineer Menu 2 " is selected .
2. Press 6 to select the 24hour Omit Group option.
3. Circuits will be displayed as O(Omitted) or A(Armed). Press 0 to
change ("toggle" action).
4. Press [ to accept (high note) and go to n ext circuit. A low tone
indicates that the circuit cannot be omitted.
5. Circuits may be selected by numb er. Press ] to quit.
23
TS700 Installation Manual Programming
01-N
Circuit 01 wi ll not chime.
Press 0 to change.
01-Y
Circuit 01 wi ll chime.
Press ENT to accept.
02-A
Circuit 02 wi ll remain Armed.
Press 0 to change.
02-O
Circuit 02 wi ll b e Omitted.
Press ENT to accept.
----
Ent er new engineer passcode.
2804
New passcode 2804 entered.
Press ENT to accept.
----
Ent er date (day & month).
0207
Date entered 0207 (02 July).
Vista de pagina 22
1 2 ... 18 19 20 21 22 23 24 25 26 27 28 ... 31 32

Comentarios a estos manuales