TECHNICAL BULLETIN
No. TS510/001/4/95
TS510 AND REMOTE KEYPADS
Problem
On some installations with remote keypads, it has been found that the control panel
sometimes responds incorrectly when using either the main or remote keypad. Some of the
symptoms include:

Spurious keypad bleeps from the control panel or remote.

Customer enters their passcode to set the system, the exit timer starts then after a few
seconds the system will return to the unset condition.
Solution
The problem may be solved by fitting a 0.1uf capacitor between terminals
E
and
C
on the
Remote Interface PCB.
If screened cable has been used on the installation, the braiding must also be connected to
terminal E on the Remote Interface PCB. The braiding at the remote keypad must be cut back
and NOT connected.