4. Part Setting using Part Set Codes
Ensure that all monitored areas are secured. Enter your
passcode, the exit sounder will make a continuous tone. If
required leave via the norma l exit route and close the final exit
door, (pressing the Exit Terminator button if fitted). The system is
part set when the exit sounder stops, the display will al ternate
betweenthe group/areawhich hasbeen armedandthecurrent
time.
5. Setting with Circuits Omitted
It may sometimes be desirable to omit a circuit when full or part
setting the system.
1. Enter your passcode (users 1-9) and press [ within 5
seconds.
2. Press 7 and the display will show the circuit number
followed by i ts omit status. N = not omitted and Y =
omitted.
3. Press0 tochangethestatusofthe circuit and[ to confirm
the change. A low tone will indicate that the circuit cann ot
be omitted or a high pitch multi-tone i ndic ates that the
change has been accepted. Continue with the next circuit
if required.
4. Press] to quitto "user menu1"andcontinue withsetting by
pressing0 for full-setor A or B or C for part-set(see 2 and
3).
6. Silent Setting
The system c an be full set or part set silently except for the final
system set sound. Enter your passcode (users 1-9) and for fullset
press 8 within 5 seconds. For part set press A or B or C then
press 8 .
Alternatively
Enter yo ur passcode (users 1-9) and press [ within 5 seconds.
Press8 and the displaywillshowSIL -.Enter 0 forsilentfullset
or A o r B or C for silent part set.
7. Setting and Unsetting With a Keyswitch
Opera tethekeyswitch (ordoor lo ck) and leave via theexit route.
The syste m will be full set or part set when the exit sounder stops.
To unset the system, operate the keyswitch (or lock) again.
3
TS700 LED User Operating Instructions
00
.
15
User passcode B entered.
Group/area B will set in 15
seconds.
B
SET
Group/area B is now armed.
1 -
‘User menu 1’ selecte d.
01-N
Circuit 01 will not be omitted.
01-Y
Press 0 to change the status.
Circuit 01 will now be omitted.
SIL-
Press [0] for silent full set or [A] or
[B] or [C] for si lent part set.
1 -
"User menu 1" selected.
Vista de pagina 4