Operating the System
1. Introduction
System operation can only be carried out after entering your
passcode. Up to twelve passcodes can be allocat ed and they
canonlybedefinedbythe"masteruser"(user1).UsersA,BandC
can only set and unset their respectiv e areas. E ntering a
passcode with the first two digits reversed will cause a "Dure ss
Alarm". Eachkeypress isacknowledgedby thekeypad sounder.
Pressing the [ES C] key takes the user back t o the previous step in
the menu.When the systemis notbeing usedthe keypad dis play
shows the current time. The "ENG ON SITE" message is displayed
afteran engineerhas lefthismenuandisclearedthe nexttimea
user passcode is entered .
2. Full Setting the System
Ensure that all monitored areas are secured. Enter your
passcode(users1 to9 on ly)and the di splay wil l show"Func".After
five seconds the display will show how much time is left b efore
the system is set and the sounder makes a continuou s tone.
Le ave via the n ormal exit route and close the final exit door
(pressing the Exit Terminator button if fitted). The system is full set
when the exit sounder stops, the display will s how ‘SET’ for five
seconds then reverts to showing the current time.
WARNING: If an attempt is made to set t he system whilst any
circuits are active (such as a door being open), the display will
indicate the circuit s that are in fault and the internal sounder
generates an i nterruptedtone. Thefault must be cleared before
the setting procedure can be completed. If t he system is set by
‘Timed Exit’ and the fault is still present at the end of the exit t ime
an internal alarm will be generated. If fitted, the external strobe
lig ht will flash indicating the system has failed to set. To prevent
thi s alarm simplyre-enteryourpasscodebeforethetimeexpires.
3. Part Setting the System (user s 1 To 9)
Ensure that all monitored areas are secured. Enter your
passcode (users 1 to 9 only) and within 5 seconds press [A] or [B]
or [C] (depending upon the part set area required). If the five
seconds is exceede d the system will full se t. The displa y shows
the selected group/area that will be omitted and the sounder
makes a continuou s tone. If required l eave via the normal exit
route and close the final exit door, (pressing the E xit Terminator
button iffitted). The system ispartsetwhentheexitsounderstops,
the display willalternate between the group/area thatisomitted
and the current time.
2
TS700 LED User Operating Instructions
This is the normal display when
the system is set or unset. The
time is displayed and the "dot"
segment flashes
22
.
34
ENG
ON
SITE
Ent er user passcode to clear
Func
User passcode entered
9999
This f igure indicates the time to
set in secs. 9999 indicates the
system is being set by Last Exit or
Exit T erminator. Any other figure
is timed exit.
SET
The display will show se t for 5
seconds, t hen revert to only
displaying the ti me.
Func
User passcode entered
OT
.
A
Omit button [A] is p ressed.
BC
SET
The display shows the group
that has been omitted (A).