Returning to the Unset Mode (key
]
)
Once all the engineer programming is completed the system can be returned to the unset
mode by pressing the
]
key. However since the speech dialler has not yet been
programmed the display will still show the "PLEASE RE-RECORD" message. This will be
cleared when one or more of the speech dialler messages have been recorded (see User
Manual for full details).
Full Setting the System (AWAY)
The engineer may use his passcode to Set the system as follows:
1 Enter first two digit of engineer's passcode then press the
]
key (e.g.,
1 2 ]
).
2 The exit tone will start and the display shows the remaining time.
3 When the exit tone stops, the system is full set.
Part-Setting the System (HOME)
The engineer may use his passcode to part-set the system as follows:
1 Enter first two digit of engineer's passcode then press the
[
key (e.g.,
1 2 [
).
2 The display shows the remaining time (part-set is always silent).
3 When the two-tone sound is heard, the system is part-set.
Unsetting the System
The engineer may only use his passcode to unset the system when the system is set or
part-set using the engineer passcode (i.e., if the system is set by the user the engineer
passcode will NOT unset the system).
1 Enter via the prescribed entry route.
2 The entry tone will start and the display will show the remaining time.
3 Enter the engineer's passcode (e.g.,
1 2 3 4
).
4 The display shows UNSET.
Programming TSD402 Installation Manual