System Options (Cont.)
1 Ensure that the "ENGR. OPTION -" is displayed. Press
9
to select System Options.
2 Press keys 1 to 7 to toggle between the two settings for each option (as Shown Below).
3 When completed, press
[
to accept, a two tone acceptance tone will be heard.
Speech Dialler Alarm Options (key
0
)
The speech dialler may be configured to trigger on a FIRE, P.A. or ALARM activations for
both the Away set and the Home set. Changing any of the alarm options does not affect
the operation of the auxiliary speech dialler input (if used).
1 Ensure that the "ENGR. OPTION -" is displayed. Press
0
to select the Dialler Alarm Options.
2 Press keys
1
-
3
or
5
-
7
to toggle each option on or off (as Shown Below).
3 When completed, press
[
to accept, a two tone acceptance tone will be heard.
E9- A T U 3 A S E
1 2 3 4 5 6 7
PressKey
ToToggle
E9- C F E 1 H D N
System Options
Display
Setting Mode= Timed Exit
System Reset = User
Keyswitch = Away Set
RST- = SW12V
F/Exit = Normal in part-set
System Re-arms= 3
Bell Output = SAB
System Reset = Engineer
Keyswitch = Home set
RST- = Detector Reset
F/Exit = Night in part-set
System Re-arms= 1
Bell Output = SCB
Setting Mode = Final Exit set
1 2 3 5 6 7
PressKey
ToToggle
Dialler Alarm
Options
Intruder reported when Home set
Firenot reported when Home set
P A not reported when Home set
Intruder not reported when Home set
Firereported when Awayset
PA reported when Awayset
Intruder reported when Awayset
Firenot reported when Awayset
PA not reported when Away set
Intruder not reported when Away set
E0- F P A - F P A
E0- -
PA reported when Home/Unset
Fire reported when Home/Unset
TSD402 Installation Manual Programming
27