User Menu 1 Walk Testing Circuits
This option allows you to periodically test the
operation of detection circuits. You can only
select or deselect the wards that you have
access to.
1. At the remote keypad enter your
passcode followed by
[.
2. Press 2 followed by [ to select the walk
test option.
3. The display will show which wards are
selected for walk test.
4. To select or deselect wardsA-Hpress 1
- 8. To select or deselect wardsI-Ppress
A then 1 - 8.
5. Once you have the required wards
selected press
[ to start the test.
6. Walk around the wards that are being
tested and operate all detection
devices. As each device is operated
there will be a chime tone from the
internal sounders and the display will
show the triggered circuit.
7. When finished press ]. Pressing [ will
allow you to scroll through the tested
circuits in a chronological order. Press
]
twice times to return the system to its
original state.
24
SYSTEM OPEN
17:30 Sun 01 JAN
User menu 1
Select option :-
User menu 1
Do Walk test
Walk test wards:
A,B,C,D,E,.,.,.,
ESC to stop test
& View circuits
Office window
2002 Active
Office door
2001 Active
Office door
2001 Active
Office window
2001 Active
SYSTEM OPEN
17:40 Sun 01 JAN
2
ENT
ENT
???? ? ? ?
ENT
ENT
ENT
Select/deselect wards
Operate detectors
e.g. Office window
& Office door
End Of test
Review tested circuits
ESC ESC
ESC
1
A/
8
C
or
-
Comentarios a estos manuales